Magnizon-Pure Sine Wave Inverter 48vdc 230v, 50/60hz, 8000w – Aps-8048sw-Lcd
KSh370,000 Original price was: KSh370,000.KSh333,600Current price is: KSh333,600. Exc. VAT
- 48V DC or 230V AC input; 230V, 50 Hz output (hardwired)
- 8KWcontinuous output, 24000 watts peak output
- Microprocessor-controlled Smart-UPS & Solar operational mode
- 4-Step Progressive Charging & 7-Battery Type Selector
- Fully compatible with Solar/Wind solutions for Hybrid configuration
- Pure sine wave output with LCD display
Magnizon-Pure Sine Wave Inverter 48vdc 230v, 50/60hz, 8000w – Aps-8048sw-Lcd
Provide Pure Sine Wave power for all your alternative energy needs with the MAGNIZON APS-8048SW-LCD. This inverter/charger supplies 8000 watts of continuous 230V /50Hz AC power.
Reliable large transformer design and frequency control powers are very much compatible with all varieties of loads: resistive loads such as refrigerators, motors, pump compressors, and laser printers as well as electronic loads like TVs, Computers, power tools, and battery chargers.
Smart microcontroller-based 3-stage charging system properly charges and maintains battery bank. The charge rate is selectable so you can use a variety of battery sizes and types to fit your backup time requirements.
Key Features
- 48V DC or 230V AC input; 230V, 50 Hz output (hardwired)
- 8KWcontinuous output, 24000 watts peak output
- Microprocessor-controlled Smart-UPS & Solar operational mode
- 4-Step Progressive Charging & 7-Battery Type Selector
- Fully compatible with Solar/Wind solutions for Hybrid configuration
- Pure sine wave output with LCD display
- High Efficiency Using Line-Interactive Circuit Topology(Full Bridge Topology)
- Quiet, high-efficiency operation, high surge capacity, and low idle current
On inverter
- High overload ability
- Low battery voltage trip selectable, extracting max power from various batteries with different protections
- Low quiescent current, selectable sensing cycle to reduce power consumption
On battery charger
- 3-step intelligent battery charging
- 8 preset battery type selectors plus de-sulphation for totally flat batteries
- Powerful charge rate up to 100Amp, selectable charging current
- PFC(Power Factor Correction) for charger, less power consumption than conventional units
On Transfer
- Delay before the transfer, extra protections for loads under generator mode
- Input AC voltage range selectable, for different kinds of loads
- 8 ms typical transfer time, guarantees power continuity
- 30A/40A through current ability
- Output voltage regulation optional
On remote control & other features
- Ability to switch the unit on/off
- Ability to select/deselect power saver mode
- 17 alarms/warnings, informative for easier operation and trouble-shooting
- LCD status display available
- RS232 communication port optional
**Built-in input and output breakers.
Applications
Provides safe and reliable power protection for the following equipment:
- Equipment is Office and Public
- Home Appliances
- IT Network Equipment
- Manufacture Control System
- Solar Energy System
- Oil Field and Fieldwork
Product Specifications
INPUT AC
Input Phase & Wave Form | Single Phase & Sine wave (Utility or Generator) |
Nominal Voltage | 220/230/240V AC |
Input AC voltage Window | 154-273C AC |
Line Low Transfer | 154V +/- 4% |
Low Voltage Re engage | 164V +/- 4% |
High Voltage Trip | 273V +/- 4% |
High Voltage Re engage | 263V +/- 4% |
Max Input AC Voltage | 270V |
Nominal Input Frequency | 50Hz or 60Hz (Auto detect) |
Low-frequency trip | 40Hz |
High-frequency trip | 80Hz |
Output Connection type | Hardwire via built-in junction box with cover plate |
INVERTER OUTPUT SPECIFICATION
Output Waveform & Phase | Pure Sine wave & Single Phase (Bypass mode sync to Input) |
Power Factor | 1 |
Nominal Output Voltage RMS | 220/230/240V AC (L-N) (same as input on Bypass mode) |
Output Voltage regulation | +/-10% RMS (bypass mode sync to input) |
Output frequency | 50Hz +/-0.3Hz or 60Hz+/-0.3Hz |
Nominal Efficiency | >88% |
Output Connection type | Hardwire via built-in junction box with cover plate |
Surge rating/crest factor | 3 times of rating |
Output continuous power in Watts | 8000 |
Output continuous power in VA | 8000 |
Short circuit protection | Yes, fault after 10sec |
DC INPUT SPECIFICATION
Nominal Input Voltage DC | 48V DC |
Minimum start voltage DC | 40V DC |
Low battery Alarm | 44V DC |
Low battery trip | 40V DC |
High Voltage Alarm | 64V DC |
Over Charge Voltage | 62.8V DC |
Max Charging Current | 75A DC |
DC Connection type | DC INPUT: Set of 2 DC bolt-down terminals. AC INPUT: Hardwire via built-in junction box with cover plate |
TRANSFER EFFICIENCY
Transfer Time | 6-10mSec |
Line Mode | >95% |
Battery Model | >85% |
Power Save | Available when the load is less than 75W |
INDICATORS/ ALARMS
4-LED Status Display | Charge, Line, Inverter & fault |
LCD Display | Input Voltage, Output Voltage, Frequency, Battery voltage, Load, Temperature, Charge current & Fault |
Switch Selector | Saving Mode is On/Off when pushing the switch forward/backward, keeping it horizontal turns the inverter Off |
Audible Alarm | Sounding when the heat sink’s temperature is over 105deg C and shutdown after 30 seconds |
Protections | Low Battery, Overcharging, Over temp & overload |
Communications | RJ11/RS232 (optional) |
ENVIRONMENTAL DETAILS
Operating Temp | 0-40deg C |
Humidity | 0-95% RH (non-condensing) |
Audible Noise | <60dB |
PHYSICAL DETAILS
Size (in mm) | 549x450x202 |
Weight | 56Kgs |
Warranty | 2 Year limited warranty Extendable up to 4 years |
Safety | EMC/CE/ROHS/ISO9001 |
CERTIFICATION/ CONFORMITY
Disturbance at Mains Terminals | EN61000-6-3:2007+ A1: 2011+ AC:2012 |
Radiated Disturbance | EN61000-6-3:2007+ A1: 2011+ AC:2012 |
Harmonic Current Emission | EN61000-3-12: 2011 |
Voltage fluctuations & flickering | EN61000-3-11: 2000 |
Electrostatic Discharge (ESD) | IEC 6100-4-2:2008 |
Radio-frequency & continued radiated disturbances | IEC 6100-4-3:2006 + A1:2007 + A2:2010 |
EFT/B Immunity | IEC 6100-4-4:2012 |
Surge immunity | IEC 6100-4-5:2014 |
Conducted RF immunity | IEC 6100-4-6:2013 |
Power frequency magnetic field | IEC 6100-4-8:2009 |
Voltage DIP | >95% reduction, IEC 6100-4-11:2004 |
Voltage DIP | >30% reduction, IEC 6100-4-11:2004 |
Voltage Interruption | IEC 6100-4-11:2004 |
Have quick look on the Datasheet for more information
Brand
Magnizon
Be the first to review “Magnizon-Pure Sine Wave Inverter 48vdc 230v, 50/60hz, 8000w – Aps-8048sw-Lcd” Cancel reply
You must be logged in to post a review.
Related products
Solar Inverters
Taico-PV6000-48 48V 5KW Single Phase Inverter (Max w/9 Parallel)
Solar Inverters
Solar Inverters
Solar Inverters
Reviews
There are no reviews yet.